Slide deck reports a 2016 field and laboratory validation of handheld X-ray fluorescence (XRF) for measuring mercury (Hg) in riverbank soils. AECOM collected 236 samples; JMU performed XRF in field and lab; results compared to EPA Method 7471A (Lancaster Labs). XRF showed strong agreement (field R2=0.9337, lab R2=0.9702), 102% spike recovery, and comparable precision.
File Type:
pdf
Categories:
Presentations
Publication Date :
1905-07-08
Type :
Presentation
Review Notes :
Slides include authors (Robert Brent, Hunter Wines, Joseph Luther) and internal study dates (field: March 7–16, 2016; lab: May 9–26, 2016). No explicit publication or presentation date is shown on the PDF; location/context inferred only from slide content. All summary points are drawn directly from the slides.